- Domestic 631824
- Blister 632079
- Domestic adaptors 632076
- Domestic cable reels 632077
- Domestic multiple sockets 632081
- Domestic plugs and sockets 632075
- Lamp holders and chamfer switches 632078
- TV/Data 632080
- Wiring devices 632082
- BASIC (8000) Series 632270
- EVOLUTION Series 632271
- EVOLVE Series 632268
- FUTURA Series 632264
- GEA Series 632266
- GLENO Series 632267
- INNOVA Series 632259
- KOMPAS Series 632260
- LUXURY Series 632263
- METALCLAD Series 632269
- MIA Series 632274
- NEXTA Series 632262
- OPERA Series 632258
- PAVIBOX Series 632265
- PROTECTA Series 632261
- UNIBOX Series +EVOLUTION 632272
- UNIBOX Series +EVOLVE 632273
- E-Mobility 631828
- AC charging stations 632630
- Charging cables 632627
- Connection 632629
- DC charging stations 632631
- E-bike charging stations 632628
- Hazardous areas Ex 631827
- Industry 631825
- Distribution assemblies 632734
- Empty enclosures 632728
- High currents industrial plugs and sockets 632727
- IOT Interlocked sockets 632737
- Industrial Plugs and Sockets 632729
- Accessories for plugs and sockets 634065
- Connectors 634071
- Domestic socket outlets 634067
- Flush mounting appliance inlets 634069
- Flush mounting socket outlets 634073
- Plugs 634068
- Plugs and sockets for specific applications 634074
- Surface mounting appliance inlets 634070
- Surface mounting socket outlets 634072
- Surface mounting socket outlets with switch 634066
- Industrial adaptors 632735
- Industrial cable reels 632736
- Light fittings 632732
- Multipolar connectors 632733
- Switched interlocked socket outlets 632730
- Switchgears 632731
- Installation 631826
Warning! You must be logged in to download documents. If not, you will be redirected to the login page
ADVANCE-GRP[GD] SERIES
INTERLOCKED SOCKET
Cod. 504.63862
63A 3P+E 2h >50V >300-500Hz II 2GD 170X380MM_PAR Screw terminals With mechanical interlock
Commercial Series
ADVANCE-GRP[GD] Series
Synthetical description
INTERLOCKED SOCKET
Mounting version
SURFACE MOUNTING
Rated current
63A
Poles
3P+E
Hour position
2h
Rated voltage (range)
50-200V
Rated voltage
>50V
Working frequency
>300-500Hz
Colour
RED
Material
GRP Glass Reinforced Polyester
Protection degree
Splash proof
Protection degree IP
IP66
Protection degree IK
IK10
Terminals
Screw terminals
Contact material
CuZn (brass)
Flange
170X380MM_PAR
Cable entry
1xM40
Working temperature
-35°C/+60°C
GLOW WIRE
GW 960°C
Self-extinguishing UL94
V0
Group and categories EX
II 2GD
Options
With mechanical interlock
Padlock
ø6,3mm
Catalogue notes
ATEX [ATmosphères EXplosibles]: por applications in potentially explosive atmospheres.
Product
EAN code
8001636298542
INTRASTAT code
8536699099
Net weight
5.662 KG
Minimum Quantity
1
Packaging
Packaging Carton
EAN code
Quantity
1
Depth
435.0 MM
Width
180.0 MM
Height
230.0 MM
Volume
18009.0 CCM
EN 60309-2/A1 (2007) | [European Standard] Plugs, socket-outlets and couplers for industrial purposes. Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories of harmonized configurations |
EN 60309-1/A1 (2007) | [European Standard] Plugs, socket-outlets and couplers for industrial purposes. Part 1: General requirements |
EN 60309-2/A2 (2012) | [European Standard] Plugs, socket-outlets and couplers for industrial purposes. - Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories of harmonized configurations |
EN 60309-4 (2007) | [European Standard] Plugs, socket-outlets and couplers for industrial purposes. Switched socket-outlets and connectors, with or without interlock |
IEC 60079-1 (2014) | [International Standard] Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d". |
DIRECTIVE ATEX 2014/34/UE | [European Directives] Atmosphere Explosive |
IEC 60079-0 (2017) | [International Standard] Explosive atmospheres - Part 0: Equipment - General requirements |
EN 60309-1 (1999) | [European Standard] Plugs, socket-outlets and couplers for industrial purposes. Part 1: General requirements |
EN 60079-7 (2018) | [European Standard] Explosive atmospheres. - Part 7: Equipment protection by increased safety "e" |
EN 60079-0 (2018) | [European Standard] Explosive atmospheres. General requirements. |
EN 60309-1/A2 (2012) | [European Standard] Plugs, socket-outlets and couplers for industrial purposes. - Part 1: General requirements |
EN 60079-1 (2014) | [European Standard] Electrical apparatus for explosive gas atmospheres - Part 1: Flameproof enclosures 'd' |
IEC 60079-31 (2013) | [International Standard] Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t" |
EN 60309-2 (1999) | [European Standard] Plugs, socket-outlets and couplers for industrial purposes. Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories of harmonized configurations |
EN 60309-4/A1 (2012) | [European Standard] Plugs, socket-outlets and couplers for industrial purposes. - Switched socket-outlets and connectors, with or without interlock |
IEC 60079-7 (2017) | [International Standard] Explosive atmospheres - Part 7: Equipment protection by increased safety "e". |
EN 60079-31 (2014) | [European Standard] Explosive atmospheres. Equipment dust ignition protection by enclosure "t" |
EN 60079-7 (2015) | [European Standard] Explosive atmospheres. Equipment protection by increased safety "e" |
UKCA marking
UK Conformity Assessed
UE
Declaration of conformity
UKCA marking [EUROFIN UKCA ATEX]
UK Conformity Assessed
INERIS IECEx
Institut National de l'Environnement Industriel et des Risques
INERIS Atex
Institut National de l'Environnement Industriel et des Risques
Notifica ATEX
Product quality assurance notification
Notifica ATEX
Product quality assurance notification