Catálogo
Warning! You must be logged in to download documents. If not, you will be redirected to the login page

SÉRIE BE-B

PILLAR BE-B

Cod. 205.B62-SS

Type 2 1P+N+T 32A 230V~ 7,4kW 32A 400V 3P+N+T IP54 IK10 Tipo 2 4m ENROLADO

Pillar in powder paint galvanized steel with 2 connectors Type 2 32A 230Vac 7,4kW with cable with the reference IEC/EN 62196-2 and located on the side on the side. Suitable for charging electric vehicles in «mode 3» in compliance with IEC/EN 61851-1 and It is particularly suited for installation in public places, this pillar is equipped with RFID Card reader for user identification and management. High degree of protection against dust and water.
Série comercial
Série BE-B
Descrição sintéica
PILLAR BE-B
Material
METAL ENVERNIZADO
Cable length
4m
Cable section
3G6+1x0,5mm²
Cable
ENROLADO
Corrente nominal
32A
Tensão nominal
400V
Frequência
50/60Hz
Polos
3P+N+T
Grau de proteção IP
IP54
Working temperature
-30/+50°C with derating 24A
Grau de proteção IK
IK10
Cor
BRONZE
Solução salina
Resistente
UV protection
UV resistant
Versão de montagem
EM CIMA DA TORRE
Dimensions
300x1466x300mm

Product

EAN code
8001636468280
INTRASTAT code
8537109899
Net weight
0 KG
Quantidade Mínima
1

Packaging

Packaging Carton
EAN code
Quantity
1
Depth
0.0
Width
0.0
Height
0.0
Volume
0.0
DIRECTIVE EMC 2014/30/UE [European Directives] Electromagnetic Compatibility Directive
IEC 61439-7 (2018) [International Standard] Low-voltage switchgear and controlgear assemblies - Part 7: Assemblies for specific applications such as marinas, camping sites, market squares, electric vehicle charging stations
DIRECTIVE LOW VOLTAGE 2014/35/UE [European Directives] Low Voltage Directive
EN IEC 61851-1 (2019) [European Standard] Electric vehicle conductive charging system - Part 1: General requirements
Version
PRO
EV standard
Type 2 1P+N+T 32A 230V~ 7,4kW
Com cabo integrado
Tipo 2
HMI (Human-Machine Interfaces)
LCD 2x20 char
User authentication
RFID authentication
Connectivity
Ethernet
WiFi
GSM
Communication protocol
OCPP 1.6 JSON
EV functions
charge in mode 3 with pwm circuit pilot
predisposition for serial communication
energy metering and current consumption
identification of authorized user
working in mode stand-alone free or personal
charge managing in case of power outage
protection against overcurrents and electric shock
power contactor aperture monitoring
interfacing with OCPP Central Station
Load Balancing function
wireless connection to web
managing of connector locking in inlet dummy
EV equipment
1 base with separation chamber
1 power supply 24Vdc 36W
1 fuse holder 1P+N gG 4A
1 backup battery
1 local server wired with OCPP 1.6J protocol
2 DC Leakage detectors
2 control cards
2 stop charge push-buttons (mode free)
2 lcd display 2x20 rows backlight
2 readers RFID 13,56MHz
1 terminal strip 5x35mm²
1 router Wi-Fi/4G
1 main switch 4P 40A
2 modular contactors 2P 40A 24Vdc
2 circuit breakers 1P+N C40 30mA ist. A
2 shunt trip releases 24Vdc
2 digital energy meters MID 1P+N 40A
2 inlets dummy with RGB led
2 inlets dummy with RGB led
2 cables 3G6+1x0,5mm² (max extension 4m)
EV specifications
Pillar in powder paint galvanized steel with sockets located on the side and illuminated with LED frame for signaling status.<br> Prepared for floor installation with basement with function of anti-condensation separation room.<br> Equipped with:<br> 2 connectors Type 2 in compliance with IEC/EN 62196-2 for mode 3 charging and case C (mobile connector with cable) in compliance with IEC/EN 61851-1, maximum supply current 32A single-phase 230Vac (7,4kW).<br> Complete with:<br> Automatic and residual current device for protection against over currents and indirect contact.<br> Digital meter for the measurement of the energy delivered and the control of current cosumption, MID certifided<br> «DC Leakage» devices for detection of contiunuos earth leakage current (>=6 mA).<br> Backup batteries to ensure continuity of service in the case of power outage.<br> «Save Unlock» system to ensure the possibility of extracting the connector in the event of a blackout.<br> RFID reader for user identification and management of the charge, working in FREE or PERSONAL stand-alone mode.<br> LCD backlit display 2x20 character, for messages and diagnostic management with the possibility to change the language through the button.<br> Push button for display language changing and STOP to end the charge and allow plug extraction in FREE mode.<br> Remote control by local server wired connectable to Central Station with OCPP 1.6J protocol.<br> Wireless connection to web by router Wi-Fi/4G<br> Operating temperature -30°C to +50°C.<br> Impact resistance IK10.<br> Enclosure with IP54 degree of protection.<br> Compliant with CEI EN 61851-1, CEI EN 62196-2, CEI EN 61439-1, CEI EN 60304-7-722 standards and complete with CE marking.<br> Lower part of the socket side customizable<br> Color BE-BRONZE<br>
RCM
Regulatory Compliance Mark
thumbnail
UKCA marking
UK Conformity Assessed
thumbnail
UE
Declaratiòn de conformidad
thumbnail
EAC
Eurasian Conformity
Você precisa da Folha Técnica do produto ?
Baixe em formato pdf
Você precisa de Documentação ou Certificação do produto ?

Tem o número de série do seu produto ?

Você precisa de Documentação ou Certificação do produto ?

Aprofundamento

Produtos relacionados

Scame Parre S.p.a
Via Costa Erta 15
24020 Parre (BG) -  Italy
Tel. 
Via Costa Erta 15
24020 Parre (BG) -  Italy

© 2023 Scame Parre S.p.a. - VAT IT00137900163