- Doméstico 637496
- Material elétrico em blister 637751
- Adaptadores domésticos 637748
- Enroladores de cabo domésticos 637749
- Tomadas múltiplas domésticas 637753
- Fichas e tomadas domésticas 637747
- Seção 1.4 637750
- TV/SAT - TEL - DATA 637752
- Wiring devices 637754
- Série BASIC (8000) 637942
- Série EVOLUTION 637943
- Série EVOLVE 637940
- Série FUTURA 637936
- Série GEA 637938
- Série GLENO 637939
- Série INNOVA 637931
- Série KOMPAS 637932
- Série LUXURY 637935
- Série METALCLAD 637941
- Série MIA 637946
- Série NEXTA 637934
- Série OPERA 637930
- Série PAVIBOX 637937
- Série PROTECTA 637933
- Série UNIBOX +EVOLUTION 637944
- Série UNIBOX +EVOLVE 637945
- E-Mobility 637500
- AC charging stations 638302
- Cabos de carregamento 638299
- Connessione 638301
- DC charging stations 638303
- E-bike charging stations 638300
- Áreas de risco Ex 637499
- Indústria 637497
- Seção 3.1 638406
- Empty enclosures 638400
- Plugues e tomadas industriais para altas correntes 638399
- Tomadas interbloqueadas IOT 638409
- Plugues e tomadas industriais 638401
- Acessórios para plugues y tomadas 639737
- Tomadas móveis industriais 639743
- Socket for domestic applications 639739
- Plugues de embutir 639741
- Tomadas de embutir 639745
- Plugues móveis 639740
- Fichas e tomadas para aplicações específicas 639746
- Plugues fixos de parede 639742
- Tomadas de parede 639744
- Tomadas de parede - SWITCH 639738
- Adaptadores industriais 638407
- Enrolador de cabo industriais 638408
- Seção 2.5 638404
- Connettori multipolari 638405
- Switched interlocked socket outlets 638402
- Interruptores 638403
- Instalação 637498
Warning! You must be logged in to download documents. If not, you will be redirected to the login page
SÉRIE BE-B
PILLAR BE-B
Cod. 205.B52-UU
Type 2 3P+N+T 32A 400V~ 22kW 63A 400V 3P+N+T IP54 IK10 Tipo 2 4m ENROLADO
Pillar in powder paint galvanized steel with 2 connectors Type 2 32A 400Vac 22kW with cable with the reference IEC/EN 62196-2 and located on the side on the side. Suitable for charging electric vehicles in «mode 3» in compliance with IEC/EN 61851-1 and It is particularly suited for installation in public places, this pillar is equipped with RFID Card reader for user identification and management. High degree of protection against dust and water.
Série comercial
Série BE-B
Descrição sintéica
PILLAR BE-B
Material
METAL ENVERNIZADO
Cable length
4m
Cable section
5G6+1x0,5mm²
Cable
ENROLADO
Corrente nominal
63A
Tensão nominal
400V
Frequência
50/60Hz
Polos
3P+N+T
Grau de proteção IP
IP54
Working temperature
-30/+50°C with derating 24A
Grau de proteção IK
IK10
Cor
BRONZE
Solução salina
Resistente
UV protection
UV resistant
Versão de montagem
EM CIMA DA TORRE
Dimensions
300x1466x300mm
Product
EAN code
8001636468235
INTRASTAT code
8537109899
Net weight
60.615 KG
Quantidade Mínima
1
Packaging
Packaging Carton
Quantity
1
EAN code
Depth
1475.0 MM
Width
468.0 MM
Height
310.0 MM
Volume
213993.0 CCM
DIRECTIVE EMC 2014/30/UE | [European Directives] Electromagnetic Compatibility Directive |
EN IEC 61851-1 (2019) | [European Standard] Electric vehicle conductive charging system - Part 1: General requirements |
IEC 61439-7 (2018) | [International Standard] Low-voltage switchgear and controlgear assemblies - Part 7: Assemblies for specific applications such as marinas, camping sites, market squares, electric vehicle charging stations |
DIRECTIVE LOW VOLTAGE 2014/35/UE | [European Directives] Low Voltage Directive |
Version
PRO
EV standard
Type 2 3P+N+T 32A 400V~ 22kW
Com cabo integrado
Tipo 2
HMI (Human-Machine Interfaces)
LCD 2x20 char
User authentication
RFID authentication
Connectivity
Ethernet
Communication protocol
OCPP 1.6 JSON
EV functions
charge in mode 3 with pwm circuit pilot
predisposition for serial communication
energy metering and current consumption
identification of authorized user
working in mode stand-alone free or personal
charge managing in case of power outage
protection against overcurrents and electric shock
interfacing with OCPP Central Station
power contactor aperture monitoring
Load Balancing function
managing of connector locking in inlet dummy
EV equipment
1 base with separation chamber
1 power supply 24Vdc 36W
1 fuse holder 1P+N gG 4A
1 backup battery
1 local server wired with OCPP 1.6J protocol
2 DC Leakage detectors
2 control cards
2 lcd display 2x20 rows backlight
2 readers RFID 13,56MHz
2 stop charge push-buttons (mode free)
1 terminal strip 5x35mm²
2 modular contactors 4P 40A 24Vdc
2 circuit breakers 3P+N C40 30mA ist. A
2 shunt trip releases 24Vdc
2 digital energy meters MID 3P+N 80A
2 inlets dummy with RGB led
2 cables 5G6+1x0,5mm² (max extension 4m)
2 inlets dummy with RGB led
1 main switch 4P 100A
EV specifications
Pillar in powder paint galvanized steel with sockets located on the side and illuminated with LED frame for signaling status.<br> Prepared for floor installation with basement with function of anti-condensation separation room.<br> Equipped with:<br> 2 connectors Type 2 in compliance with IEC/EN 62196-2 for mode 3 charging and case C (mobile connector with cable) in compliance with IEC/EN 61851-1, maximum supply current 32A three-phase 400Vac (22kW).<br> Complete with:<br> Automatic and residual current device for protection against over currents and indirect contact.<br> Digital meter for the measurement of the energy delivered and the control of current cosumption, MID certifided<br> «DC Leakage» devices for detection of contiunuos earth leakage current (>=6 mA).<br> Backup batteries to ensure continuity of service in the case of power outage.<br> «Save Unlock» system to ensure the possibility of extracting the connector in the event of a blackout.<br> RFID reader for user identification and management of the charge, working in FREE or PERSONAL stand-alone mode.<br> LCD backlit display 2x20 character, for messages and diagnostic management with the possibility to change the language through the button.<br> Push button for display language changing and STOP to end the charge and allow plug extraction in FREE mode.<br> Remote control by local server wired connectable to Central Station with OCPP 1.6J protocol.<br> Operating temperature -30°C to +50°C.<br> Impact resistance IK10.<br> Enclosure with IP54 degree of protection.<br> Compliant with CEI EN 61851-1, CEI EN 62196-2, CEI EN 61439-1, CEI EN 60304-7-722 standards and complete with CE marking.<br> Lower part of the socket side customizable<br> Color BE-BRONZE<br>
RCM
Regulatory Compliance Mark
UKCA marking
UK Conformity Assessed
UE
Declaratiòn de conformidad
EAC
Eurasian Conformity