Type 2 3P+N+T 32A 400V~ 22kW 80A 400V 3P+N+T IP54 IK10

Ver produto de substituição
Painted steel column equipped with 2 Type 2 3P+N+T 32A 400 Vac 22 kW sockets and 2 Type 3A 1P+N+T 16A 230 Vac 3.5 kW sockets with safety shutters in compliance with IEC/EN 62196-2 Suitable for charging electric vehicles in «mode 3» in compliance with IEC/EN 61851-1. It is particularly suited for installation in public places. Equipped with RFID Card for user identification and management. Allows the simultaneous charging of four vehicles Charging station with sockets equipped with special plug locking system and with exclusive anti-vandal access system (Type 2). Customisable panel, resistant to UVA rays, high degree of protection against dust and water (IP54)
Série comercial
Série CA
Descrição sintéica
PILLAR CA 4 SOCKETS WITH LOCK
Material
METAL ENVERNIZADO
Corrente nominal
80A
Tensão nominal
400V
Frequência
50/60Hz
Polos
3P+N+T
Grau de proteção IP
IP54
Working temperature
-30°C/+50°C
Grau de proteção IK
IK10
Cor
CINZA
Solução salina
Resistente
UV protection
UV resistant
Versão de montagem
EM CIMA DA TORRE
Dimensions
385x1510x263mm

Product

EAN code
8001636312811
INTRASTAT code
8537109899
Net weight
54.75 KG
Quantidade Mínima
0

Packaging

Packaging Carton
EAN code
Quantity
1
Depth
0.0
Width
0.0
Height
0.0
Volume
0.0
DIRECTIVE EMC 2014/30/UE [European Directives] Electromagnetic Compatibility Directive
IEC 61439-7 (2018) [International Standard] Low-voltage switchgear and controlgear assemblies - Part 7: Assemblies for specific applications such as marinas, camping sites, market squares, electric vehicle charging stations
DIRECTIVE LOW VOLTAGE 2014/35/UE [European Directives] Low Voltage Directive
EN IEC 61851-1 (2019) [European Standard] Electric vehicle conductive charging system - Part 1: General requirements
Version
BUSINESS
EV standard
Type 2 3P+N+T 32A 400V~ 22kW
HMI (Human-Machine Interfaces)
LCD 2x20 char
User authentication
RFID authentication
Connectivity
None
EV functions
charge in mode 3 with pwm circuit pilot
predisposition for serial communication
energy metering and current consumption
identification of authorized user
working in mode stand-alone free or personal
protection against direct contact Safety Child Shutters
charge managing in case of power outage
identification of connected cord-set size
protection against overcurrents and electric shock
managing of lid locking and latching system
EV equipment
1 base with separation chamber
1 fuse holder 1P+N gG 4A
1 backup battery
1 lighting head in translucent and RGB led
1 terminal strip 5x35mm²
1 couple of front panels in polycarbonate
1 main switch 4P 80A
2 circuit breakers 1P+N D20 30mA ist. A
4 DC Leakage detectors
4 control cards
2 circuit breakers 3P+N C40 30mA ist. A
1 power supply 24Vdc 60W
2 digital energy meters 1P+N 40A
2 modular contactors 4P 40A 24Vdc
4 lcd display 2x20 rows backlight
4 readers RFID 13,56MHz
4 stop charge push-buttons (mode free)
2 modular contactors 2P 25A 24Vdc
2 digital energy meters 3P+N 80A
EV specifications
Charging station for electric vehicles with floor installation via galvanised steel base (500 X 410 mm) acting as a condensation separation chamber, equipped with studs on which to fix the column using M8 nuts (centre distance 250 X 170 mm).<br>Structure in galvanised and painted sheet steel equipped with front panels in plexiglass with the possibility of customisation with the customer's logo or brand.<br>RGB LED light head with three colours indicating the station's operating status.<br>Column equipped with four sockets: two type 2 anti-vandal and two type 3A with protective shutters compliant with the CEI EN 62196-2 standard and suited for charging in mode 3 in compliance with the CEI EN 61851-1 standard (IPXXD degree of protection is guaranteed without further disconnecting devices).<br>Sockets equipped with plug locking system and interlocking of the cover to prevent tampering and unauthorised access.<br>Maximum deliverable current 32 A three-phase (22 kW) with identification of the connected cable size for the type 2 sockets and 16 A single-phase (3.5 kW) for the type 3A sockets.<br>Column complete with automatic and differential protection devices (type B for three-phase socket) and digital meter for the measurement of the energy delivered and the control of the absorbed current.<br>LCD display for messages and diagnostic management with the possibility of changing the language through a simple button, backup batteries to ensure continuity of service in the event of power loss.<br>RFID reader for user recognition and management of the charge. Operation in FREE or PERSONAL stand-alone mode.<br>STOP button to end the charge and allow plug extraction (FREE mode).<br>Set up for communication over RS485 serial line (NET mode with management via server).<br>Operating temperature -25°C to +40°C, IK10 impact resistance, casing with IP54 degree of protection.<br>Compliant with CEI EN 61851-1, CEI EN 62196-2, CEI EN 61439-7, CEI EN 60304-7-722 standards and complete with CE marking.<br>
thumbnail
UKCA marking
UK Conformity Assessed
thumbnail
UE
Declaratiòn de conformidad
Você precisa da Folha Técnica do produto ?
Baixe em formato pdf
Você precisa de Documentação ou Certificação do produto ?

Tem o número de série do seu produto ?

Você precisa de Documentação ou Certificação do produto ?

Aprofundamento

Produtos relacionados

Scame Parre S.p.a
Via Costa Erta 15
24020 Parre (BG) -  Italy
Tel. 
Via Costa Erta 15
24020 Parre (BG) -  Italy

© 2023 Scame Parre S.p.a. - VAT IT00137900163