Type 2 1P+N+T 16A 230V~ 3,7kW 16A 400V 3P+N+T IP54 IK10 Tipo 2 3m

Em exaustão
Painted steel column equipped with 2 Type 2 1P+N+T 16A 230 Vac 3.5 kW sockets in compliance with IEC/EN 62196-2 Suitable for charging electric vehicles in «mode 3» in compliance with the IEC/EN 61851-1 standard with type-C connection. Particularly suitable for installation in public areas. Equipped with RFID Card for user identification and management Charging station with sockets having a special system that checks for the correct opening of the contactor. Customisable panel, resistant to UVA rays, high degree of protection against dust and water (IP54)
Série comercial
Série CA
Descrição sintéica
PILLAR CA 2 CONNECTORS RFID
Material
METAL ENVERNIZADO
Cable length
3m
Cable section
3G2,5+1x0,5mm²
Corrente nominal
16A
Tensão nominal
400V
Frequência
50/60Hz
Polos
3P+N+T
Grau de proteção IP
IP54
Working temperature
-30°C/+50°C
Grau de proteção IK
IK10
Cor
CINZA
Solução salina
Resistente
UV protection
UV resistant
Versão de montagem
EM CIMA DA TORRE
Dimensions
385x1510x263mm

Product

EAN code
8001636290591
INTRASTAT code
8537109899
Net weight
53 KG
Quantidade Mínima
1

Packaging

Packaging Carton
EAN code
Quantity
1
Depth
0.0
Width
0.0
Height
0.0
Volume
0.0
DIRECTIVE EMC 2014/30/UE [European Directives] Electromagnetic Compatibility Directive
IEC 61439-7 (2018) [International Standard] Low-voltage switchgear and controlgear assemblies - Part 7: Assemblies for specific applications such as marinas, camping sites, market squares, electric vehicle charging stations
EN IEC 61851-1 (2019) [European Standard] Electric vehicle conductive charging system - Part 1: General requirements
DIRECTIVE LOW VOLTAGE 2014/35/UE [European Directives] Low Voltage Directive
Version
BUSINESS
EV standard
Type 2 1P+N+T 16A 230V~ 3,7kW
Com cabo integrado
Tipo 2
HMI (Human-Machine Interfaces)
LCD 2x20 char
User authentication
RFID authentication
Connectivity
None
EV functions
charge in mode 3 with pwm circuit pilot
predisposition for serial communication
energy metering and current consumption
identification of authorized user
working in mode stand-alone free or personal
charge managing in case of power outage
protection against overcurrents and electric shock
power contactor aperture monitoring
EV equipment
1 base with separation chamber
1 power supply 24Vdc 36W
1 fuse holder 1P+N gG 4A
1 backup battery
2 DC Leakage detectors
2 control cards
2 stop charge push-buttons (mode free)
2 lcd display 2x20 rows backlight
2 readers RFID 13,56MHz
1 lighting head in translucent and RGB led
1 terminal strip 5x35mm²
1 couple of front panels in polycarbonate
1 main switch 4P 40A
2 circuit breakers 1P+N D20 30mA ist. A
2 shunt trip releases 24Vdc
2 digital energy meters 1P+N 40A
2 inlets dummy for connector storage
2 cables 3G2,5+1x0,5mm² 3m
2 modular contactors 2P 25A 24Vdc
EV specifications
Charging station for electric vehicles with floor installation via galvanised steel base (500 X 410 mm) acting as a condensation separation chamber, equipped with studs on which to fix the column using M8 nuts (centre distance 250 X 170 mm).<br>Structure in galvanised and painted sheet steel equipped with front panels in plexiglass with the possibility of customisation with the customer's logo or brand.<br>RGB LED light head with three colours indicating the station's operating status.<br>Column equipped with two type 2 mobile sockets (cable + mobile connector corresponding to a case C connection) in compliance with CEI EN 62196-2 and suitable for charging in mode 3 in compliance with CEI EN 61851-1.<br>The socket unit is mounted onto the vehicle to avoid tampering and disconnections while charging.<br>The IPXXD degree of protection required by the standard is provided through a control system to verify the correct opening of the power contactor.<br>Maximum deliverable current 16 A single-phase (3.5 kW) for each socket.<br>Column complete with automatic and differential protection devices and digital meter for the measurement of the energy delivered and the control of the absorbed current.<br>LCD display for messages and diagnostic management with the possibility of changing the language through a simple button, backup batteries to ensure continuity of service in the event of power loss.<br>RFID reader for user recognition and management of the charge. Operation in FREE or PERSONAL stand-alone mode.<br>Set up for communication over RS485 serial line (NET mode with management via server).<br>Operating temperature -25°C to +40°C, IK10 impact resistance, casing with IP44 degree of protection.<br>Compliant with CEI EN 61851-1, CEI EN 62196-2, CEI EN 61439-7, CEI EN 60304-7-722 standards and complete with CE marking.<br>
thumbnail
UKCA marking
UK Conformity Assessed
thumbnail
UE
Declaratiòn de conformidad
Você precisa da Folha Técnica do produto ?
Baixe em formato pdf
Você precisa de Documentação ou Certificação do produto ?

Tem o número de série do seu produto ?

Você precisa de Documentação ou Certificação do produto ?

Aprofundamento

Produtos relacionados

Scame Parre S.p.a
Via Costa Erta 15
24020 Parre (BG) -  Italy
Tel. 
Via Costa Erta 15
24020 Parre (BG) -  Italy

© 2023 Scame Parre S.p.a. - VAT IT00137900163