SÉRIE BE-W

Type 2 3P+N+T 32A 400V~ 22kW 32A 400V 3P+N+T IP54 IK08 OCPP 1.6 JSON

Cod. 205.W69-D0

WALL BOX 1 PRISE TYPE 2

Hors Production Voir le produit de remplacement
Smart Wall Box in halogen-free engineering plastics, for wall assembly, equipped with display and Type 2 socket, 3P+N+E 32A 400V, 22kW, fitted with safety shutters in compliance with standard IEC/EN 62196-2, equipped with Energy Meter, and RFID user identification and authorisation system.
Suitable for electric vehicle charging in «mode 3» in compliance with standard EN61851-1. Version for domestic charging in absolute safety, featuring Power Management function, allowing the vehicle charging current to be adapted based on the user’s contractual power and the current absorbed by domestic loads, thus preventing the main meter from unexpectedly tripping.
The WEB-NET version allows remote monitoring through our standard Management System. Exclusive design with «Dual Feel Sensitive» finish, highly resistant to UV rays, high-level IP54 protection against dust and water with the possibility for personalisation.
Série commerciale
Série BE-W
Description
WALL BOX 1 PRISE TYPE 2
Matériau
Technopolymère
Courant nominal
32A
Tension nominale
400V
Fréquence d'utilisation
50/60Hz
Pôles
3P+N+T
Indice de protection IP
IP54
Température de fonctionnement
-30°C/+50°C
Fil incandescent
650°C
Indice de protection IK
IK08
Couleur
ANTHRACITE
Solution saline
Résistant
UV protection
UV resistant
Type de installation
MONTAGE SAILLIE
Dimensions
235x370x115mm

Product

EAN code
8001636447803
INTRASTAT code
8537109899
Net weight
4.412 KG
Quantité minimum
1

Packaging

Packaging Carton
EAN code
Quantity
1
Depth
640.0 MM
Width
320.0 MM
Height
140.0 MM
Volume
28672.0 CCM
IEC 61439-7 (2018) [International Standard] Low-voltage switchgear and controlgear assemblies - Part 7: Assemblies for specific applications such as marinas, camping sites, market squares, electric vehicle charging stations
EN IEC 61851-1 (2019) [European Standard] Electric vehicle conductive charging system - Part 1: General requirements
DIRECTIVE EMC 2014/30/UE [European Directives] Electromagnetic Compatibility Directive
DIRECTIVE LOW VOLTAGE 2014/35/UE [European Directives] Low Voltage Directive
Version
PRO
EV standard
Type 2 3P+N+T 32A 400V~ 22kW
IHM (Interfaces Homme-Machine)
LCD 2x20 char
Authentification d'utilisateur
Authentification RFID
Connectivité
Ethernet
Protocole de communication
OCPP 1.6 JSON
EV functions
charge in mode 3 with pwm circuit pilot
predisposition for serial communication
energy metering and current consumption
identification of authorized user
protection against direct contact Safety Child Shutters
working in mode stand-alone free or personal
charge managing in case of power outage
identification of connected cord-set size
interfacing with OCPP Central Station
managing of latching system
POWER MANAGEMENT function (automatic modulation of charge current depending contractual power and power used by house).
EV equipment
1 terminal strip 5x10mm²
1 power supply 24Vdc 36W
1 fuse holder 1P+N gG 4A
1 DC Leakage detector
1 control card
1 stop charge push-button (mode free)
1 lcd display 2x20 rows backlight
1 RBG led stripes
1 backup battery
1 reader RFID 13,56MHz
1 local server wired with OCPP 1.6J protocol
1 modular contactor 4P 40A 24Vdc
1 digital energy meter 3P+N 80A
1 digital energy meter 3P+N 65/80A (external)
EV excluded
upstream protections (by the installer):
1 circuit breaker 3P+N C40 30mA ist. A
EV capitolato
Wall mounting box in thermoplastic material halogen free resistant to impact and UV rays.<br> Equipped with:<br> 1 socket Type 2 in compliance with IEC/EN 62196-2 for mode 3 charging in compliance with IEC/EN 61851-1, equipped with shutter protection (IPXXD degree of protection without any additional devides), plug latching system to avoid unintetional withdraw under load, maximum supply current 32A three-phase 400Vac (22kW).<br> Automatic modulation of charge current depending contractual power and power used by house.<br> Complete with:<br> Digital meter for the measurement of the energy delivered and the control of current cosumption.<br> «DC Leakage» devices for detection of contiunuos earth leakage current (>=6 mA).<br> Backup batteries to ensure continuity of service in the case of power outage.<br> RFID reader for user identification and management of the charge, working in FREE or PERSONAL stand-alone mode.<br> LCD backlit display 2x20 character, for messages and diagnostic management with the possibility to change the language through the button.<br> Push button for display language changing and STOP to end the charge and allow plug extraction in FREE mode.<br> Set up for communication over RS485 serial line (NET mode with management via server).<br> Remote control by local server wired connectable to Central Station with OCPP 1.6J protocol.<br> Provide suitable upstream protection designed on load and line length.<br> Operating temperature -30°C to +50°C.<br> Impact resistance IK08.<br> Enclosure with IP54 degree of protection.<br> Compliant with CEI EN 61851-1, CEI EN 62196-2, CEI EN 61439-1, CEI EN 60304-7-722 standards and complete with CE marking.
RCM
Regulatory Compliance Mark
thumbnail
UKCA marking
UK Conformity Assessed
thumbnail
UE
Déclaration de conformité
thumbnail
EAC
Eurasian Conformity
Avez-vous besoin de la fiche technique du produit au format pdf et imprimable?
Télécharger la Fiche Technique
Vous avez besoin de documentation technique, de manuels, de fiches d’instructions ou de certificats ?

Avez-vous le numéro de série de votre produit ?

Approfondissements

Scame Parre S.p.a
Via Costa Erta 15
24020 Parre (BG) -  Italy
Via Costa Erta 15
24020 Parre (BG) -  Italy

© 2023 Scame Parre S.p.a.