Catalogue
Warning! You must be logged in to download documents. If not, you will be redirected to the login page

SÉRIE BE-T

WALL BOX 1 PRISE TYPE 2

Cod. 205.T85-BCB

Type 2 1P+N+T 32A 230V~ 7,4kW 32A 230V 1P+N+T IP54 IK09 OCPP 1.6 JSON

Série commerciale
Série BE-T
Description
WALL BOX 1 PRISE TYPE 2
Matériau
Technopolymère
Courant nominal
32A
Tension nominale
230V
Fréquence d'utilisation
50/60Hz
Pôles
1P+N+T
Indice de protection IP
IP54
Température de fonctionnement
-30°C/+50°C
Fil incandescent
650°C
Indice de protection IK
IK09
Couleur
ANTHRACITE
Finition du panneau avant
CUSTOM
Finition du cadre
BRONZE
Solution saline
Résistant
UV protection
UV resistant
Type de installation
MONTAGE SAILLIE
Dimensions
245x660x120mm

Product

EAN code
8001636159201
INTRASTAT code
8537109899
Net weight
0 KG
Quantité minimum
1

Packaging

Packaging Carton
EAN code
Quantity
1
Depth
690.0 MM
Width
400.0 MM
Height
140.0 MM
Volume
38640.0 CCM
DIRECTIVE EMC 2014/30/UE [European Directives] Electromagnetic Compatibility Directive
IEC 61439-7 (2018) [International Standard] Low-voltage switchgear and controlgear assemblies - Part 7: Assemblies for specific applications such as marinas, camping sites, market squares, electric vehicle charging stations
EN IEC 61851-1 (2019) [European Standard] Electric vehicle conductive charging system - Part 1: General requirements
DIRECTIVE LOW VOLTAGE 2014/35/UE [European Directives] Low Voltage Directive
Version
PRO
EV standard
Type 2 1P+N+T 32A 230V~ 7,4kW
IHM (Interfaces Homme-Machine)
LCD 2x20 char
Authentification d'utilisateur
Authentification RFID
Connectivité
Ethernet
WiFi
GSM
Protocole de communication
OCPP 1.6 JSON
EV functions
charge in mode 3 with pwm circuit pilot
predisposition for serial communication
energy metering and current consumption
identification of authorized user
working in mode stand-alone free or personal
protection against direct contact Safety Child Shutters
identification of connected cord-set size
charge managing in case of power outage
interfacing with OCPP Central Station
managing of lid locking and latching system
POWER MANAGEMENT function embedded
Load Balancing function
wireless connection to web
EV equipment
1 fuse holder 1P+N gG 4A
1 power supply 24Vdc 36W
1 DC Leakage detector
1 control card
1 RBG led stripes
1 stop charge push-button (mode free)
1 lcd display 2x20 rows backlight
1 backup battery
1 reader RFID 13,56MHz
1 modular contactor 2P 40A 24Vdc
1 local server wired with OCPP 1.6J protocol
1 painted metallic frame
1 terminal strip 5x16mm²
1 router Wi-Fi/4G
1 digital energy meter MID 1P+N 40A
EV excluded
upstream protections (by the installer):
1 circuit breaker 1P+N C40 30mA ist. A
EV capitolato
Wall mounting box in thermoplastic material halogen free resistant to impact and UV rays.<br> Equipped with:<br> 1 socket Type 2 in compliance with IEC/EN 62196-2 for mode 3 charging in compliance with IEC/EN 61851-1, equipped with shutter protection (IPXXD degree of protection without any additional devides), plug latching system to avoid unintetional withdraw under load, maximum supply current 32A single-phase 230Vac (7,4kW).<br> Complete with:<br> Digital meter for the measurement of the energy delivered and the control of current cosumption, MID certifided.<br> «DC Leakage» devices for detection of contiunuos earth leakage current (>=6 mA).<br> «Save Unlock» system to ensure the possibility of extracting the connector in the event of a blackout.<br> RFID reader for user identification and management of the charge, working in FREE or PERSONAL stand-alone mode.<br> LCD backlit display 2x20 character, for messages and diagnostic management with the possibility to change the language through the button.<br> Push button for display language changing and STOP to end the charge and allow plug extraction in FREE mode.<br> Set up for communication over RS485 serial line (NET mode with management via server).<br> Remote control by local server wired connectable to Central Station with OCPP 1.6J protocol.<br> Wireless connection to web by router Wi-Fi/4G Provide suitable upstream protection designed on load and line length.<br> Operating temperature -30°C to +50°C.<br> Impact resistance IK09.<br> Enclosure with IP54 degree of protection.<br> Front side customizable with color printer and painted metal frame.<br> Compliant with CEI EN 61851-1, CEI EN 62196-2, CEI EN 61439-1 and complete with CE marking.<br>
RCM
Regulatory Compliance Mark
thumbnail
UKCA marking
UK Conformity Assessed
thumbnail
UE
Déclaration de conformité
thumbnail
EAC
Eurasian Conformity
Avez-vous besoin de la fiche technique du produit au format pdf et imprimable?
Télécharger la Fiche Technique
Vous avez besoin de documentation technique, de manuels, de fiches d’instructions ou de certificats ?

Avez-vous le numéro de série de votre produit ?

Avez-vous besoin de visualiser le produit en 3D ?

Approfondissements

Scame Parre S.p.a
Via Costa Erta 15
24020 Parre (BG) -  Italy
Via Costa Erta 15
24020 Parre (BG) -  Italy

© 2023 Scame Parre S.p.a.