- Doméstico 628988
- Productos en blister 629243
- Adaptadores domésticos 629240
- Enrollacables domesticos 629241
- Bases múltiples domésticas 629245
- Clavijas y bases domésticas 629239
- Portalámparas e interruptores 629242
- TV/DATA 629244
- Mecanismos 629246
- Serie BASIC (8000) 629434
- Serie EVOLUTION 629435
- Serie EVOLVE 629432
- Serie FUTURA 629428
- Serie GEA 629430
- Serie GLENO 629431
- Serie INNOVA 629423
- Serie KOMPAS 629424
- Serie LUXURY 629427
- Serie METALCLAD 629433
- Serie MIA 629438
- Serie NEXTA 629426
- Serie OPERA 629422
- Serie PAVIBOX 629429
- Serie PROTECTA 629425
- Serie UNIBOX +EVOLUTION 629436
- Serie UNIBOX +EVOLVE 629437
- E-Mobility 628992
- Estaciones de carga en AC 629794
- Cables de carga 629791
- Conexiones 629793
- Estaciones de recarga en DC 629795
- Estaciones de carga para e-bike 629792
- Ambientes potencialmente explosivos ATEX 628991
- Industria 628989
- Cuadros cableados 629898
- Envolventes 629892
- Clavijas y bases industriales de alta intensidad 629891
- Bases con bloqueo IOT 629901
- Clavijas y bases industriales 629893
- Adaptadores industriales 629899
- Enrollacables industriales 629900
- Aparatos de iluminación 629896
- Connettori multipolari 629897
- Bases con dispositivo de bloqueo 629894
- Interruptores 629895
- Instalación 628990
¡Advertencia! Para poder descargar la documentación, debes haber iniciado sesión, ingresando tu nombre de usuario y contraseña. De lo contrario, será redirigido a la página de inicio de sesión.
SERIE ADVANCE-GRP[<50V]
BASE CON BLOQUEO
Cod. 503.2416-F
16A 2P 24V II 3D Bornes con tornillo Con enclavamiento eléctrico
Serie comercial
Serie ADVANCE-GRP[<50V]
Descripción
BASE CON BLOQUEO
Intensidad nominal
16A
Polos
2P
Tensión nominal (range)
0-50V
Tensión nominal
24V
Color
VIOLETA
Material
GRP Glass Reinforced Polyester
Grado de protección
Splash proof
Grado de protección IP
IP66
Grado de protección IK
IK10
Bornes
Bornes con tornillo
Material de los contactos
CuZn (latón)
Temperatura de ejercicio
-40°C/+60°C
Prueba del hilo incandescente
GW 960°C
Autoextinguible UL94
V0
Grupo y categorías EX
II 3D
Modo de protección Polvo
Ex tc IIIC T90°C Dc IP66
Temperatura ambiente Ta min
-25 °C
Temperatura ambiente Ta max
60 °C
Opciones
Con enclavamiento eléctrico
Notas
CON TRASFORMATORE 120VA
Catalogue notes
Pared lisa con marca del punto de perforación
Fusibles no suministrados
Transformador SELV 220/24V~ 150VA (servicio contínuo).
Product
EAN code
8001636238005
INTRASTAT code
8536699099
Net weight
5.861 KG
Cantidad mínima
1
Packaging
Packaging Carton
EAN code
Quantity
1
Depth
515.0 MM
Width
140.0 MM
Height
180.0 MM
Volume
12978.0 CCM
EN 60309-1/A1 (2007) | [European Standard] Plugs, socket-outlets and couplers for industrial purposes. Part 1: General requirements |
EN 61558-1/A11 (2003) | [European Standard] Safety of power transformers, power supply units and similar. General requirements and tests |
EN 60309-2/A1 (2007) | [European Standard] Plugs, socket-outlets and couplers for industrial purposes. Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories of harmonized configurations |
EN 61558-2-6 (1997) | [European Standard] Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating saf[...].. |
EN 61558-1 (1997) | [European Standard] Safety of power transformers, power supply units and similar. General requirements and tests |
EN 60309-2/A2 (2012) | [European Standard] Plugs, socket-outlets and couplers for industrial purposes. - Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories of harmonized configurations |
EN 60309-1/A2 (2012) | [European Standard] Plugs, socket-outlets and couplers for industrial purposes. - Part 1: General requirements |
EN 61558-1/A1 (1998) | [European Standard] Safety of power transformers, power supply units and similar. General requirements and tests |
EN 60309-2 (1999) | [European Standard] Plugs, socket-outlets and couplers for industrial purposes. Part 2: Dimensional interchangeability requirements for pin and contact-tube accessories of harmonized configurations |
DIRECTIVE ATEX 2014/34/UE | [European Directives] Atmosphere Explosive |
EN 60309-1 (1999) | [European Standard] Plugs, socket-outlets and couplers for industrial purposes. Part 1: General requirements |
EN 60079-0 (2012) | [European Standard] Explosive atmospheres. General requirements. |
DIRECTIVE EMC 2014/30/UE | [European Directives] Electromagnetic Compatibility Directive |
EN 60079-31 (2014) | [European Standard] Explosive atmospheres. Equipment dust ignition protection by enclosure "t" |
EN 60079-0/A11 (2013) | [European Standard] Explosive atmospheres. General requirements. |
DIRECTIVE LOW VOLTAGE 2014/35/UE | [European Directives] Low Voltage Directive |
SCAME Ex
ATEX
UKCA marking
UK Conformity Assessed
UE
Declaratiòn de conformidad
EAC
Eurasian Conformity