- Doméstico 637496
- Productos en blister 637751
- Adaptadores domésticos 637748
- Enrollacables domesticos 637749
- Bases múltiples domésticas 637753
- Clavijas y bases domésticas 637747
- Portalámparas e interruptores 637750
- TV/DATA 637752
- Mecanismos 637754
- Serie BASIC (8000) 637942
- Serie EVOLUTION 637943
- Serie EVOLVE 637940
- Serie FUTURA 637936
- Serie GEA 637938
- Serie GLENO 637939
- Serie INNOVA 637931
- Serie KOMPAS 637932
- Serie LUXURY 637935
- Serie METALCLAD 637941
- Serie MIA 637946
- Serie NEXTA 637934
- Serie OPERA 637930
- Serie PAVIBOX 637937
- Serie PROTECTA 637933
- Serie UNIBOX +EVOLUTION 637944
- Serie UNIBOX +EVOLVE 637945
- E-Mobility 637500
- Estaciones de carga en AC 638302
- Cables de carga 638299
- Conexiones 638301
- Estaciones de recarga en DC 638303
- Estaciones de carga para e-bike 638300
- Áreas peligrosas Ex 637499
- Industria 637497
- Cuadros cableados 638406
- Envolventes 638400
- Clavijas y bases industriales de alta intensidad 638399
- Bases con bloqueo IOT 638409
- Clavijas y bases industriales 638401
- Adaptadores industriales 638407
- Enrollacables industriales 638408
- Aparatos de iluminación 638404
- Connettori multipolari 638405
- Bases con dispositivo de bloqueo 638402
- Interruptores 638403
- Instalación 637498
Warning! You must be logged in to download documents. If not, you will be redirected to the login page
SERIE CA
COLUMNA CA 4 BASES CON BLOQUEO
Cod. 204.CA41B-004A
DE 2P+T 16A 230V~ 3,7kW 32A 400V 3P+N+T IP54 IK10 OCPP 1.6 JSON
Serie comercial
Serie CA
Descripción
COLUMNA CA 4 BASES CON BLOQUEO
Material
METAL BARNIZADO
Intensidad nominal
32A
Tensión nominal
400V
Frecuencia nominal
50/60Hz
Polos
3P+N+T
Grado de protección IP
IP54
Temperatura de ejercicio
-30°C/+50°C
Grado de protección IK
IK10
Color
GRIS
Solución salina
Resistente
UV protection
UV resistant
Tipo de instalación
TORRETA
Dimensiones
385x1510x263mm
Product
EAN code
8001636437620
INTRASTAT code
8537109899
Net weight
55 KG
Cantidad mínima
1
EN 61439-3 (2012-04) | [European Standard] Low-voltage switchgear and controlgear assemblies - Part 3: Distribution boards intended to be operated by ordinary persons (DBO) |
DIRECTIVE EMC 2014/30/UE | [European Directives] Electromagnetic Compatibility Directive |
DIRECTIVE LOW VOLTAGE 2014/35/UE | [European Directives] Low Voltage Directive |
Versión
PRO
EV standard
DE 2P+T 16A 230V~ 3,7kW
IHM (Interface Hombre-Máquina)
LCD 2x20 char
Autenticacion de usuario
Autenticación RFID
Connectivity
Ethernet
Protocolo de comunicación
OCPP 1.6 JSON
EV funciones
protection against overcurrents and electric shock
predisposition for serial communication
energy metering and current consumption
identification of authorized user
working in mode stand-alone free or personal
protection against direct contact Safety Child Shutters
charge managing in case of power outage
interfacing with OCPP Central Station
managing of lid locking and latching system
Load Balancing function
EV equipo
1 base with separation chamber
1 fuse holder 1P+N gG 4A
1 backup battery
1 local server wired with OCPP 1.6J protocol
1 lighting head in translucent and RGB led
1 terminal strip 5x35mm²
1 couple of front panels in polycarbonate
1 main switch 4P 40A
4 circuit breakers 1P+N D20 30mA ist. A
4 lcd display 2x20 rows backlight
4 readers RFID 13,56MHz
4 stop charge push-buttons (mode free)
4 modular contactors 2P 25A 24Vdc
1 power supply 24Vdc 60W
4 control cards
4 digital energy meters 1P+N 40A
EV capitolato
Pillar in painted galvanized steel prepared for floor installation with basement with function of anti-condensation separation room.<br> RGB LED light head with three colours indicating the station's operating status.<br> Front panels in polycarbonate with the possibility of customization with the customer's logo or brand.<br> Equipped with:<br> 4 German sockets type (domestic), equipped with shutter protection (IPXXD degree of protection without any additional devides), lockable lid even with plug inserted to avoid unintentional withdraw, maximum supply current 16A single-phase 230Vac (3,7kW), the use of this sockets is allowed only in areas where is not compulsory the mode 3.<br> Complete with:<br> Automatic and residual current device for protection against over currents and indirect contact.<br> Digital meter for the measurement of the energy delivered and the control of current cosumption.<br> Backup batteries to ensure continuity of service in the case of power outage.<br> «Save Unlock» system to ensure the possibility of extracting the connector in the event of a blackout.<br> RFID reader for user identification and management of the charge, working in FREE or PERSONAL stand-alone mode.<br> LCD backlit display 2x20 character, for messages and diagnostic management with the possibility to change the language through the button.<br> Push button for display language changing and STOP to end the charge and allow plug extraction in FREE mode.<br> Set up for communication over RS485 serial line (NET mode with management via server).<br> Remote control by local server wired connectable to Central Station with OCPP 1.6J protocol.<br> Operating temperature -30°C to +50°C.<br> Impact resistance IK10.<br> Enclosure with IP54 degree of protection.<br> Compliant with EN 61439-3 standards and complete with CE marking.<br>
UKCA marking
UK Conformity Assessed
UE
Declaratiòn de conformidad