Catálogo
Warning! You must be logged in to download documents. If not, you will be redirected to the login page

SERIE CA

COLUMNA CA 1 BASE CON BLOQUEO

Cod. 204.CA11B-UN

DE 2P+T 16A 230V~ 3,7kW 16A 230V 1P+N+T IP54 IK10

Fuera de Producción
Painted steel column equipped with 1 GERMAN (domestic) Type 1P+N+T 16A 230 Vac 3.5 kW socket in compliance with IEC 60884-1 Suitable for charging electric vehicles in «mode 1» in compliance with IEC/EN 61851-1. Particularly suited for installation in environments where mode 3 is not mandatory. Equipped with RFID Card for user identification and management Charging station with socket having a plug locking system to prevent accidental removal, realised by locking the lid opening even when the plug is inserted. Customisable panel, resistant to UVA rays, high degree of protection against dust and water (IP54)
Serie comercial
Serie CA
Descripción
COLUMNA CA 1 BASE CON BLOQUEO
Material
METAL BARNIZADO
Intensidad nominal
16A
Tensión nominal
230V
Frecuencia nominal
50/60Hz
Polos
1P+N+T
Grado de protección IP
IP54
Temperatura de ejercicio
-30°C/+50°C
Grado de protección IK
IK10
Color
GRIS
Solución salina
Resistente
UV protection
UV resistant
Tipo de instalación
TORRETA
Dimensiones
385x1510x263mm

Product

EAN code
8001636290553
INTRASTAT code
8537109899
Net weight
49 KG
Cantidad mínima
1

Packaging

Packaging Carton
EAN code
Quantity
1
Depth
0.0
Width
0.0
Height
0.0
Volume
0.0
EN 61439-3 (2012-04) [European Standard] Low-voltage switchgear and controlgear assemblies - Part 3: Distribution boards intended to be operated by ordinary persons (DBO)
DIRECTIVE EMC 2014/30/UE [European Directives] Electromagnetic Compatibility Directive
DIRECTIVE LOW VOLTAGE 2014/35/UE [European Directives] Low Voltage Directive
Versión
BUSINESS
EV standard
DE 2P+T 16A 230V~ 3,7kW
IHM (Interface Hombre-Máquina)
LCD 2x20 char
Autenticacion de usuario
Autenticación RFID
EV funciones
protection against overcurrents and electric shock
predisposition for serial communication
energy metering and current consumption
identification of authorized user
protection against direct contact Safety Child Shutters
working in mode stand-alone free or personal
charge managing in case of power outage
managing of lid locking and latching system
EV equipo
1 base with separation chamber
1 power supply 24Vdc 36W
1 fuse holder 1P+N gG 4A
1 control card
1 stop charge push-button (mode free)
1 backup battery
1 lcd display 2x20 rows backlight
1 reader RFID 13,56MHz
1 digital energy meter 1P+N 40A
1 lighting head in translucent and RGB led
1 couple of front panels in polycarbonate
1 circuit breaker 1P+N D20 30mA ist. A
1 modular contactor 2P 25A 24Vdc
1 terminal strip 3x35mm²
EV capitolato
Pillar in painted galvanized steel prepared for floor installation with basement with function of anti-condensation separation room.<br> RGB LED light head with three colours indicating the station's operating status.<br> Front panels in polycarbonate with the possibility of customization with the customer's logo or brand.<br> Equipped with:<br> 1 German socket type (domestic), equipped with shutter protection (IPXXD degree of protection without any additional devides), lockable lid even with plug inserted to avoid unintentional withdraw, maximum supply current 16A single-phase 230Vac (3,7kW), the use of this socket is allowed only in areas where is not compulsory the mode 3.<br> Complete with:<br> Automatic and residual current device for protection against over currents and indirect contact.<br> Digital meter for the measurement of the energy delivered and the control of current cosumption.<br> Backup batteries to ensure continuity of service in the case of power outage.<br> «Save Unlock» system to ensure the possibility of extracting the connector in the event of a blackout.<br> RFID reader for user identification and management of the charge, working in FREE or PERSONAL stand-alone mode.<br> LCD backlit display 2x20 character, for messages and diagnostic management with the possibility to change the language through the button.<br> Push button for display language changing and STOP to end the charge and allow plug extraction in FREE mode.<br> Set up for communication over RS485 serial line (NET mode with management via server).<br> Operating temperature -30°C to +50°C.<br> Impact resistance IK10.<br> Enclosure with IP54 degree of protection.<br> Compliant with EN 61439-3 standards and complete with CE marking.<br>
thumbnail
UKCA marking
UK Conformity Assessed
thumbnail
UE
Declaratiòn de conformidad
¿Necesita la fiche técnica del producto en formato pdf e imprimible?
Descargar la Ficha Técnica
¿Necesita documentación técnica, manuales, hojas de instrucciones o certificados?

¿Tiene el número de serie de su producto ?

¿Necesita documentación técnica, manuales, hojas de instrucciones o certificados?

Profundización

Productos relacionados

PROTECCIÓN CONTRA IMPACTOS

Serie LIBERA

PROTECCIÓN CONTRA IMPACTOS ø60 1200x500mm

Cod. 208.AP31

Scame Parre S.p.a
Via Costa Erta 15
24020 Parre (BG) -  Italy
Via Costa Erta 15
24020 Parre (BG) -  Italy

© 2023 Scame Parre S.p.a. - VAT IT00137900163