Catalog
Warning!  You must be logged in to download documents. If not, you will be redirected to the login page

BE-B SERIES

PILLAR BE-B

Cod. 205.B59-CC

Type 2 3P+N+E 16A 400V~ 11kW 32A 400V 3P+N+E IP54 IK10

Pillar in powder paint galvanized steel with 2 sockets Type 2 16A 400Vac 11 kW compliant with the reference IEC/EN 62196-2 and located on the side on the side Suitable for charging electric vehicles in «mode 3» in compliance with IEC/EN 61851-1 and It is particularly suited for installation in public places, this pillar is equipped with RFID Card reader for user identification and management. The sockets are equipped with protection shutters to ensure IPXXD degree of protection and the exclusive lighting makes possible to identify the operating status. The sockets are also equipped with special plug locking system and with exclusive anti-vandal access system that allows the insertion with one hand facilitating the charging operations. High degree of protection against dust and water.
Commercial Series
BE-B Series
Synthetical description
PILLAR BE-B
Material
VARNISHED METAL
Rated current
32A
Rated voltage
400V
Working frequency
50/60Hz
Poles
3P+N+E
Protection degree IP
IP54
Working temperature
-30/+50°C with derating 24A
Protection degree IK
IK10
Colour
BRONZE
Saline solution
Resistant
UV protection
UV resistant
Mounting version
ON TURRET
Dimensions
300x1466x300mm

Product

EAN code
8001636122595
INTRASTAT code
8537109899
Net weight
0 KG
Minimum Quantity
1

Packaging

Packaging Carton
EAN code
Quantity
1
Depth
0.0
Width
0.0
Height
0.0
Volume
0.0
DIRECTIVE EMC 2014/30/UE [European Directives] Electromagnetic Compatibility Directive
DIRECTIVE LOW VOLTAGE 2014/35/UE [European Directives] Low Voltage Directive
IEC 61439-7 (2018) [International Standard] Low-voltage switchgear and controlgear assemblies - Part 7: Assemblies for specific applications such as marinas, camping sites, market squares, electric vehicle charging stations
EN IEC 61851-1 (2019) [European Standard] Electric vehicle conductive charging system - Part 1: General requirements
Version
PRO
EV standard
Type 2 3P+N+E 16A 400V~ 11kW
HMI (Human-Machine Interfaces)
LCD 7'' push button commands
User authentication
RFID authentication
Connectivity
Ethernet
EV functions
charge in mode 3 with pwm circuit pilot
predisposition for serial communication
energy metering and current consumption
identification of authorized user
working in mode stand-alone free or personal
protection against direct contact Safety Child Shutters
charge managing in case of power outage
identification of connected cord-set size
protection against overcurrents and electric shock
managing of lid locking and latching system
Load Balancing function
interfacing with OCPP Central Station
EV equipment
1 base with separation chamber
1 fuse holder 1P+N gG 4A
1 backup battery
2 DC Leakage detectors
2 control cards
2 readers RFID 13,56MHz
1 terminal strip 5x35mm²
1 main switch 4P 40A
2 circuit breakers 3P+N C20 30mA ist. A
2 TFT 7'' color touch screen display
2 sockets located on the side with RGB Led
2 digital energy meters MID 3P+N 80A
1 power supply 24Vdc 60W
2 modular contactors 4P 25A 24Vdc
1 local server wired with OCPP 1.6J protocol
EV specifications
Pillar in powder paint galvanized steel with sockets located on the side and illuminated with LED frame for signaling status.<br> Prepared for floor installation with basement with function of anti-condensation separation room.<br> Equipped with:<br> 2 sockets Type 2 in compliance with IEC/EN 62196-2 for mode 3 charging in compliance with IEC/EN 61851-1, equipped with shutter protection (IPXXD degree of protection without any additional devides), plug latching system to avoid unintetional withdraw under load, vandal-proof lockable lid, maximum supply current 16A three-phase 400Vac (11kW).<br> Complete with:<br> Automatic and residual current device for protection against over currents and indirect contact.<br> Digital meter for the measurement of the energy delivered and the control of current cosumption, MID certifided «DC Leakage» devices for detection of contiunuos earth leakage current (>=6 mA).<br> Backup batteries to ensure continuity of service in the case of power outage.<br> «Save Unlook» system to ensure the possibility of extracting the connector in the event of a blackout.<br> RFID reader for user identification and management of the charge, working in FREE or PERSONAL stand-alone mode.<br> LCD TFT color display 7in touch screen, for messages and diagnostic management.<br> Set up for communication over RS485 serial line (NET mode with management via server).<br> Operating temperature -30°C to +50°C.<br> Impact resistance IK10.<br> Enclosure with IP54 degree of protection.<br> Compliant with CEI EN 61851-1, CEI EN 62196-2, CEI EN 61439-7, CEI EN 60304-7-722 standards and complete with CE marking.<br> Lower part of the socket side customizable.<br> Color BE-BRONZE
thumbnail
UKCA marking
UK Conformity Assessed
thumbnail
UE
Declaration of conformity
thumbnail
EAC
Eurasian Conformity
RCM
Regulatory Compliance Mark
Do you need the product techical sheet in a pdf and printable format?
Download  the Technical Sheet
Do you need technical documentation, manuals, instruction sheets or certificates?

Do you have the serial number of your product ?

Do you need to view the 3D model of the product?

Insights

Related Products

Scame Parre S.p.a Branch
Dubai Silicon Oasis
Lynx Business Tower - Office No. 208
P.O. Box 341349
Dubai – United Arab Emirates
Phone: 

Scame Parre S.p.a.

Via Costa Erta 15
24020 Parre (BG) -  Italy 

© 2023 Scame Parre S.p.a. - VAT IT00137900163