Catalog
Warning!  You must be logged in to download documents. If not, you will be redirected to the login page

WD SERIES

WALL BOX 2 SOCKETS WITH LOCK

Cod. 204.WD22B-T23A

Type 2 3P+N+E 32A 400V~ 22kW Type 3A 1P+N+E 16A 230V~ 3,7kW 50A 400V 3P+N+E IP54 IK10

Out of Production View replacement product
Wall Box made of thermoplastic material and painted steel sheet, for wall mounting, equipped with 1 Type 2 3P+N+T 32A 400 Vac 22 kW socket and 1 Type 3A 1P+N+T 16A 230 Vac 3.5 kW socket with safety shutters in compliance with IEC/EN 62196-2 Suitable for charging electric vehicles in «mode 3» in compliance with EN61851-1. Equipped with RFID Card for user identification and management. Performs like a column but more compact Charging station with sockets equipped with special plug locking system, Type 2 socket with exclusive anti-vandal access system. Resistant to UVA rays, high degree of protection against dust and water (IP54), shock resistant according to IK10. Possibility
Commercial Series
WD Series
Synthetical description
WALL BOX 2 SOCKETS WITH LOCK
Material
ENGINEERING PLASTIC
Rated current
50A
Rated voltage
400V
Working frequency
50/60Hz
Poles
3P+N+E
Protection degree IP
IP54
Working temperature
-30°C/+50°C
GLOW WIRE
GW 650°C
Protection degree IK
IK10
Colour
GREY
Saline solution
Resistant
UV protection
UV resistant
Mounting version
SURFACE MOUNTING
Dimensions
360x780x264mm

Product

EAN code
8001636319643
INTRASTAT code
8537109899
Net weight
14.79 KG
Minimum Quantity
1

Packaging

Packaging Carton
Quantity
1
EAN code
Depth
800.0 MM
Width
375.0 MM
Height
295.0 MM
Volume
88500.0 CCM
DIRECTIVE EMC 2014/30/UE [European Directives] Electromagnetic Compatibility Directive
IEC 61439-7 (2018) [International Standard] Low-voltage switchgear and controlgear assemblies - Part 7: Assemblies for specific applications such as marinas, camping sites, market squares, electric vehicle charging stations
DIRECTIVE LOW VOLTAGE 2014/35/UE [European Directives] Low Voltage Directive
EN IEC 61851-1 (2019) [European Standard] Electric vehicle conductive charging system - Part 1: General requirements
Version
PRO
EV standard
Type 2 3P+N+E 32A 400V~ 22kW
Type 3A 1P+N+E 16A 230V~ 3,7kW
HMI (Human-Machine Interfaces)
LCD 2x20 char
User authentication
RFID authentication
Connectivity
None
EV functions
charge in mode 3 with pwm circuit pilot
predisposition for serial communication
energy metering and current consumption
identification of authorized user
working in mode stand-alone free or personal
protection against direct contact Safety Child Shutters
charge managing in case of power outage
identification of connected cord-set size
protection against overcurrents and electric shock
managing of lid locking and latching system
EV equipment
2 lighting bars with RGB led
1 power supply 24Vdc 36W
1 fuse holder 1P+N gG 4A
1 backup battery
1 modular contactor 4P 40A 24Vdc
2 DC Leakage detectors
2 control cards
2 stop charge push-buttons (mode free)
1 digital energy meter 1P+N 40A
2 lcd display 2x20 rows backlight
2 readers RFID 13,56MHz
1 digital energy meter 3P+N 80A
1 circuit breaker 3P+N C40 30mA ist. A
1 modular contactor 2P 25A 24Vdc
1 terminal strip 1x35mm²
1 circuit breaker 1P+N D20 30mA ist. A
1 main switch 4P 80A
EV specifications
Charging station for electric vehicles with wall installation (or on a tubular support) made of grey technopolymer and steel sheet resistant to impact and UV rays, IP54 degree of protection, size 360 x 793 x 264 mm.Container with RGB LED strip with three colours indicating the station's operating status.<br>Column equipped with a type 2 anti-vandal socket and a type 3A socket with protective shutters compliant with the CEI EN 62196-2 standard and suitable for charging in mode 3 in compliance with the CEI EN 61851-1 standard (IPXXD degree of protection is guaranteed without further disconnecting devices).<br>Sockets equipped with plug locking system and interlocking of the cover to prevent tampering and unauthorised access.<br>Maximum deliverable current 32 A three-phase (22 kW) with identification of the connected cable size for the type 2 socket and 16 A single-phase (3.5 kW) for the type 3A socket.<br>Station complete with automatic and differential protection devices and digital meter for the measurement of the energy delivered and the control of the absorbed current.<br>LCD display for messages and managing diagnostics with the possibility of changing the language through a simple button.<br>RFID reader for user recognition and management of the charge. Operation in FREE or PERSONAL stand-alone mode.<br>STOP button to end the charge and allow plug extraction (FREE mode).<br>Set up for external 24 V DC emergency power supply system to guarantee continuity of service in case of main AC power failure.<br>Set up for communication over RS485 serial line (NET mode with management via server).<br>Operating temperature -25°C to +40°C, IK10 impact resistance, casing with IP54 degree of protection.<br>Possibility of accessorising the station with tubular support and galvanised steel plate.<br>Compliant with CEI EN 61851-1, CEI EN 62196-2, CEI EN 61439-7, CEI EN 60304-7-722 standards and complete with CE marking.<br>
thumbnail
UKCA marking
UK Conformity Assessed
thumbnail
UE
Declaration of conformity
thumbnail
EAC
Eurasian Conformity
Do you need the product techical sheet in a pdf and printable format?
Download  the Technical Sheet
Do you need technical documentation, manuals, instruction sheets or certificates?

Do you have the serial number of your product ?

Do you need to view the 3D model of the product?

Insights

Related Products

Scame Parre S.p.a Branch
Dubai Silicon Oasis
Lynx Business Tower - Office No. 208
P.O. Box 341349
Dubai – United Arab Emirates
Phone: 

Scame Parre S.p.a.

Via Costa Erta 15
24020 Parre (BG) -  Italy 

© 2023 Scame Parre S.p.a. - VAT IT00137900163