[International Standard] Low-voltage switchgear and controlgear assemblies - Part 7: Assemblies for specific applications such as marinas, camping sites, market squares, electric vehicle charging stations
EN IEC 61851-1 (2019)
[European Standard] Electric vehicle conductive charging system - Part 1: General requirements
protection against overcurrents and electric shock
interfacing with OCPP Central Station
power contactor aperture monitoring
EV equipment
1 power supply 24Vdc 36W
1 fuse holder 1P+N gG 4A
1 DC Leakage detector
1 control card
1 stop charge push-button (mode free)
1 lcd display 2x20 rows backlight
1 RBG led stripes
1 reader RFID 13,56MHz
1 local server wired with OCPP 1.6J protocol
1 modular contactor 2P 40A 24Vdc
1 circuit breaker 1P+N C40 30mA ist. A
1 digital energy meter 1P+N 40A
1 cable holder in technopolymer
1 terminal strip 3x10mm²
1 shunt trip release 24Vdc
1 cable 3G6+1x0,5mm² 4m
EV specifications
Wall mounting box in thermoplastic material halogen free resistant to impact and UV rays.<br> Equipped with:<br> 1 connector Type 2 in compliance with IEC/EN 62196-2 for mode 3 charging and case C (mobile connector with cable) in compliance with IEC/EN 61851-1, maximum supply current 32A single-phase 230Vac (7,4kW).<br> Complete with:<br> Automatic and residual current device for protection against over currents and indirect contact.<br> Digital meter for the measurement of the energy delivered and the control of current cosumption.<br> Control system for power contactor aperture monitoring.<br> «DC Leakage» devices for detection of contiunuos earth leakage current (>=6 mA).<br> RFID reader for user identification and management of the charge, working in FREE or PERSONAL stand-alone mode.<br> LCD backlit display 2x20 character, for messages and diagnostic management with the possibility to change the language through the button.<br> Push button for display language changing and STOP to end the charge and allow plug extraction in FREE mode.<br> Remote control by local server wired connectable to Central Station with OCPP 1.6J protocol.<br> Operating temperature -30°C to +50°C.<br> Impact resistance IK08.<br> Enclosure with IP54 degree of protection.<br> Compliant with CEI EN 61851-1, CEI EN 62196-2, CEI EN 61439-1, CEI EN 60304-7-722 standards and complete with CE marking.<br>