Catalog
Warning! You must be logged in to download documents. If not, you will be redirected to the login page

BE-B SERIES

PILLAR BE-B

Cod. 205.B59-TT

Type 2 3P+N+E 16A 400V~ 11kW 32A 400V 3P+N+E IP54 IK10 Type 2 4m SPIRAL

Pillar in powder paint galvanized steel with 2 connectors Type 2 16A 400Vac 11kW with cable with the reference IEC/EN 62196-2 and located on the side on the side Suitable for charging electric vehicles in «mode 3» in compliance with IEC/EN 61851-1 and It is particularly suited for installation in public places, this pillar is equipped with RFID Card reader for user identification and management. High degree of protection against dust and water.
Commercial Series
BE-B Series
Synthetical description
PILLAR BE-B
Material
VARNISHED METAL
Cable length
4m
Cable section
5G2,5+1x0,5mm²
Cable
SPIRAL
Rated current
32A
Rated voltage
400V
Working frequency
50/60Hz
Poles
3P+N+E
Protection degree IP
IP54
Working temperature
-30/+50°C with derating 24A
Protection degree IK
IK10
Colour
BRONZE
Saline solution
Resistant
UV protection
UV resistant
Mounting version
ON TURRET
Dimensions
300x1466x300mm

Product

EAN code
8001636122625
INTRASTAT code
8537109899
Net weight
0 KG
Minimum Quantity
1

Packaging

Packaging Carton
EAN code
Quantity
1
Depth
0.0
Width
0.0
Height
0.0
Volume
0.0
DIRECTIVE EMC 2014/30/UE [European Directives] Electromagnetic Compatibility Directive
IEC 61439-7 (2018) [International Standard] Low-voltage switchgear and controlgear assemblies - Part 7: Assemblies for specific applications such as marinas, camping sites, market squares, electric vehicle charging stations
DIRECTIVE LOW VOLTAGE 2014/35/UE [European Directives] Low Voltage Directive
EN IEC 61851-1 (2019) [European Standard] Electric vehicle conductive charging system - Part 1: General requirements
Version
PRO
EV standard
Type 2 3P+N+E 16A 400V~ 11kW
With integrated cable
Type 2
HMI (Human-Machine Interfaces)
LCD 7'' push button commands
User authentication
RFID authentication
EV functions
charge in mode 3 with pwm circuit pilot
predisposition for serial communication
energy metering and current consumption
identification of authorized user
working in mode stand-alone free or personal
charge managing in case of power outage
protection against overcurrents and electric shock
power contactor aperture monitoring
managing of connector locking in inlet dummy
EV equipment
1 base with separation chamber
1 fuse holder 1P+N gG 4A
1 backup battery
2 DC Leakage detectors
2 control cards
2 readers RFID 13,56MHz
1 terminal strip 5x35mm²
1 main switch 4P 40A
2 shunt trip releases 24Vdc
2 inlets dummy with RGB led
2 circuit breakers 3P+N C20 30mA ist. A
1 power supply 24Vdc 60W
2 TFT 7'' color touch screen display
2 digital energy meters MID 3P+N 80A
2 cables 5G2,5+1x0,5mm² (max extension 4m)
2 modular contactors 4P 25A 24Vdc
EV specifications
Pillar in powder paint galvanized steel with cable sockets located on the side and illuminated with LED frame for signaling status with RGB LED stripe with three colours indicating the station's operating status.<br> Prepared for floor installation with basement with function of anti-condensation separation room.<br> Equipped with:<br> 2 connectors Type 2 in compliance with IEC/EN 62196-2 for mode 3 charging and case C (mobile connector with cable) in compliance with IEC/EN 61851-1, maximum supply current 16A three-phase 400Vac (11kW).<br> Complete with:<br> Automatic and residual current device for protection against over currents and indirect contact.<br> Digital meter for the measurement of the energy delivered and the control of current cosumption, MID certifided Control system for power contactor aperture monitoring.<br> «DC Leakage» devices for detection of contiunuos earth leakage current (>=6 mA).<br> Backup batteries to ensure continuity of service in the case of power outage.<br> «Save Unlook» system to ensure the possibility of extracting the connector in the event of a blackout.<br> RFID reader for user identification and management of the charge, working in FREE or PERSONAL stand-alone mode.<br> LCD TFT color display 7in touch screen, for messages and diagnostic management.<br> Remote control by local server wired connectable to Central Station with OCPP 1.6J/5 protocol.<br> Operating temperature -30°C to +50°C.<br> Impact resistance IK10.<br> Enclosure with IP54 degree of protection.<br> Compliant with CEI EN 61851-1, CEI EN 62196-2, CEI EN 61439-7, CEI EN 60304-7-722 standards and complete with CE marking.<br> Lower part of the socket side customizable.<br> Color BE-BRONZE
thumbnail
UKCA marking
UK Conformity Assessed
thumbnail
UE
Declaration of conformity
thumbnail
EAC
Eurasian Conformity
RCM
Regulatory Compliance Mark
Do you need the product techical sheet in a pdf and printable format?
Download  the Technical Sheet
Do you need technical documentation, manuals, instruction sheets or certificates?

Do you have the serial number of your product ?

Do you need to view the 3D model of the product?

Insights

Related Products

Scame Parre S.p.a
Via Costa Erta 15 - 24020 Parre (BG) -  Italy
Phone 
Centro di informazione Tecnica 800-018009

© 2023 Scame Parre S.p.a. - VAT IT00137900163